NEGATIVE PRESSURE AMBULANCE
The Timak Negative Pressure Ambulance is a Fully Equipped Life Support Ambulance with A Negative Pressure Air System
- Designed for the transport of patients with airborne contagious diseases.
- It is fitted with a HEPA filter that traps minuscule contagions and prevents them from escaping to the environment.
- The inside air pressure is kept 12Pa lower than the surrounding environment, thereby preventing the natural flow of air from inside to outside. The air circulation system replenishes the air twelve times within an hour.
- Designed for the transport of patients with airborne contagious diseases.
- It is fitted with a HEPA filter that traps minuscule contagions and prevents them from escaping to the environment.
- The inside air pressure is kept 12Pa lower than the surrounding environment, thereby preventing the natural flow of air from inside to outside. The air circulation system replenishes the air twelve times within an hour.
How the Negative Pressure System Works
- The TIMAK Negative Pressure Ambulance has a negative pressure air filtration system for the transport of patients with airborne contagious diseases.
- The air pressure inside the ambulance is kept 12Pa lower than the outer air pressure.
- Due to the pressure difference, air from the inside is prevented from escaping to the surrounding environment.
- The Negative Pressure Ambulance is fitted with one or two HEPA filters (depending on vehicle type).
- HEPA or high-efficiency particulate absorbing filters, trap contagions as tiny as 0.3 microns, which include viruses and bacteria.
- It is fitted with UV light emitting LED rods that disinfect the air by breaking down a virus’ outer protein cover and rendering it inactive.
- An air circulation system replenishes the air within the patient area twelve times per hour.
STANDARD FEATURES | ||
Ambulance body with white painting, base electrical system, ceiling grab handle and floor covering | Air conditioning with germicidal UV light unit | Box interior lighting – manual switch control |
Digital clock | Ambulance reflective decals and strips | Electrical 2000W inverter system |
220V x 4, 12V x2, 5V USB x 4) | Emergency LED Lights – ambulance body | Exterior work lights x 3 |
Fire extinguisher (1kg, cabin mount) | First aid kit – EN1789 | Front-rear intercom system |
Foldable attendant seat (rear-facing seat) | Main stretcher with loading ramp and mounting base | Main stretcher with loading ramp and mounting base |
PA system and siren | Patient bench seat with underneath storage and lap belts | Rear access step |
Reversing alarm | Reversing camera | Roof ventilator *Deselect when negative pressure system presents |
Secondary battery system | Suspension upgrade | Window tint, ambulance body |
OPTIONAL FEATURES | ||
Electric winch | Enhanced fuel filtration system (warm climate) | High performance brake discs & pads (front) |
LED emergency lightbar | Negative pressure systems with HEPA air filter *Roof ventilator to be removed if selected | Rubbish bin |
Side steps | Two oxygen cylinders with mountings ( 679L | Two oxygen cylinders with mountings (3455L) |
MEDICAL EQUIPMENT | ||
Electric suction aspirator | Extrication collar | Finger pulse oximeter |
Head immobilization | Pole stretcher | Portable defibrillator |
Portable oxygen set with regulator kit (425L) | Portable ventilator with assist control | Resuscitator |
Scoop stretcher | Spine board | Sphygmomanometer – manual (wall mount) |
Sphygmomanometer – manual (wall mount) | Sphygmomanometer – automatic |
If you are interest this product